Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

FTN Screening Conductor Cables

 

Application

The cables are designed to be used for the purpose of screening telecommunication cables from electrical

interference.

Standards

NR/PS/TEL/31102(BR1817)

BS 6485

Construction

FTN Screening Conductor Cables

Conductors

Single core stranded aluminium to BS 215PT1.

Insulation

PVC type 16 to BS 6485 or LSZH.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 150 250
Maximum DC Conductor Resistance Ω/km 0.1825 0.1083

Mechanical and Thermal Properties

Minimum Bending Radius: 9×OD

Temperature Range:0℃ to +70℃ (during operation);

                                 0℃ to +55℃ (during installation)

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross
Sectional Area
No.×mm²
No. & Nominal Diameter of
Strands
No/mm
Nominal Thickness of
Insulation
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
RF31102-H07V-U-450/750V-1G150AL 1×150 19/3.25 1.6 19.45 629
RF31102-H07V-U-450/750V-1G250AL 1×250 19/4.22 1.6 24.30 995

U is changed to K if the stranding class is changed from class 2 to class 5